Search results for " Endovascular Procedures"
showing 10 items of 13 documents
How to diagnose and treat abdominal compartment syndrome after endovascular and open repair of ruptured abdominal aortic aneurysms
2014
Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are frequently encountered in patients treated for ruptured abdominal aortic aneurysms (rAAA) and carry a high morbidity and mortality risk. Despite these facts, IAH/ACS are still overlooked by many physicians, timely diagnosis is missed and treatment often inadequate. All staff involved in the treatment of rAAA should be aware of the risk factors predicting IAH/ACS, the profound implications and derangements on all organ systems, the clinical presentation, the appropriate measurement of intra-abdominal pressure to detect IAH/ACS and the current treatment options for these detrimental syndromes. This comprehensive r…
Periscopes, chimneys, sandwich and VORTEC to facilitate abdominal and thoracoabdominal aortic aneurysm repair
2012
The VORTEC (VIABAHN open revascularization technique) and the chimney graft technique are tools with which to maintain or restore blood flow to the aortic branches and can be used intentionally or as a bailout procedure in open surgery or endovascular procedures. VORTEC is a stent graft-based vascular connection technique that achieves end-to-end anastomosis configuration; it is especially useful when the traditional suture technique proves (can be) cumbersome. It is also a speedy tool with virtually no blood flow interruption and no anastomotic bleeding, and patency rates compare favorably with sutured anastomosis. The chimney/periscope, as well as the sandwich graft technique (CHIMPES), i…
The use of Endurant stent-graft for abdominal aortic aneurysm: the story about extension of instruction for use with persistent good results of stent…
2012
The Endurant stent-graft (Medtronic, Inc., Minneapolis, MN, USA) is a latest generation device for the treatment of abdominal aortic aneurysm. The idea behind designing such a graft came from the intention to broad the instruction for use (IFU) and to enable it to treat more challenging anatomy including the 10mm neck lengths, and more severe suprarenal and infrarenal angulations. Endurant stent-graft has active fixation through suprarenal stent with anchoring pins to provide migration resistance, optimized heights of stents and spacing between them for improved flexibility and conformability, low-profile delivery system with hydrophilic coating and controlled simple deployment mechanism. S…
A New Off-Pump Hybrid Open and Endovascular Repair to Treat Ductus Botalli and Ascendens Aneurysms
2012
To report a combined ascending aorta and aortic arch hybrid repair, we performed off-pump with no aortic graft replacement. A 65-year-old man, developing progressive recurrent laryngeal nerve paralysis, underwent a computed tomography (CT) angiography detecting nonpatent residual ductus Botalli aneurysm and ascending aorta aneurysm. Due to severe multimorbidities, a less-invasive alternative was elaborated. In a first step, appropriate proximal landing zone for aortic stent grafting was achieved by ascending aorta diameter reduction, with epiaortic wrapping, and debranching the supra-aortic trunks. In the second step, endovascular stent grafts were deployed from proximal ascending aorta to…
Recanalization Therapies in Acute Ischemic Stroke Patients Impact of Prior Treatment With Novel Oral Anticoagulants on Bleeding Complications and Out…
2015
Background— We explored the safety of intravenous thrombolysis (IVT) or intra-arterial treatment (IAT) in patients with ischemic stroke on non-vitamin K antagonist oral anticoagulants (NOACs, last intake <48 hours) in comparison with patients (1) taking vitamin K antagonists (VKAs) or (2) without previous anticoagulation (no-OAC). Methods and Results— This is a multicenter cohort pilot study. Primary outcome measures were (1) occurrence of intracranial hemorrhage (ICH) in 3 categories: any ICH (ICH any ), symptomatic ICH according to the criteria of the European Cooperative Acute Stroke Study II (ECASS-II) (sICH ECASS-II ) and the National Institute of Neurological Disorders and Stroke …
Endovascular treatment of large and wide aortic neck: case report and literature review
2017
Large (24–34 mm) and wide (≥35 mm) aortic necks are a contraindication to endovascular aneurysm repair (EVAR). A 63-year-old man, unfit for conventional surgery, presented a 79 mm abdominal aortic aneurysm with 36.5 mm aortic neck and a 62 mm right common iliac artery aneurysm. He was treated endovascularly with standard commercially available stent-graft using the so-called ‘funnel technique’; by placing a thoracic stent-graft inside a bifurcated device to achieve proximal sealing. The completion angiography and the 6 months follow-up with computed tomography showed no stent-graft migration, limb occlusion or endoleak. The literature review reported 179 cases of large aortic neck managed w…
MRI patient selection for endovascular thrombectomy in acute ischemic stroke: correlation between pretreatment diffusion weighted imaging and outcome…
2018
Introduction: Eligibility for endovascular treatment (EVT) in patients with acute ischemic stroke (AIS) depends, amongst other factors, on CT- or MR-based scores. The aim of this study was to investigate the role of Alberta Stroke Program Early CT score based on diffusion weighted imaging (MR-ASPECT) in the assessment of brain damage pre-EVT, patient selection for EVT and outcome. Materials and methods: We included in this study patients with National Institute of Health stroke score (NIHSS) at admission ≥ 8, MR-ASPECT ≥ 5 and anterior AIS, who were treated with EVT in our hospital. All patients were clinically evaluated at admission, post-EVT, discharge and at 3-month follow-up. We used MR…
Early outcomes with a single-sided access endovascular stent
2018
Abstract Objective The objective of this study was to report the 1-year follow-up study results of the new Horizon stent graft (Endospan, Herzliya, Israel) from two different prospective consecutive trials. The Horizon abdominal aortic aneurysm stent graft system is a 14F profile system requiring only a single access site. It consists of three modules, introduced separately: base limb (iliac to iliac limb); distal aortic limb; and proximal aortic limb with a bare suprarenal crown and active fixation. Methods Data from the first in man (FIM) clinical study with 10 patients enrolled and the pivotal study with 30 patients were analyzed. Outcomes measured were freedom from major adverse events …
Surgical conversion with graft salvage as a definitive treatment for persistent type II endoleak causing sacenlargement
2015
Objective The goal of this study was to present open surgical conversion with graft salvage or "semiconversion" as a definitive and safe treatment for untreatable and persistent type II endoleaks causing sac enlargement after endovascular aneurysm repair. Methods Between January 2001 and December 2014, 25 of 1623 endovascular aortic repair (EVAR) patients were selected as candidates for open semiconversion. The indication was persistent type II endoleak in 13 patients (12 of whom received previous attempts of embolization), type I and II endoleak in 2 patients, and sac growth without imaging evidence of endoleak in the other 10. After the infrarenal aorta was prepared (via a retroperitoneal…
Collected World Experience About the Performance of the Snorkel/Chimney Endovascular Technique in the Treatment of Complex Aortic Pathologies
2015
OBJECTIVES: We sought to analyze the collected worldwide experience with use of snorkel/chimney endovascular aneurysm repair (EVAR) for complex abdominal aneurysm treatment. BACKGROUND: EVAR has largely replaced open surgery worldwide for anatomically suitable aortic aneurysms. Lack of availability of fenestrated and branched devices has encouraged an alternative strategy utilizing parallel or snorkel/chimney grafts (ch-EVAR). METHODS: Clinical and radiographic information was retrospectively reviewed and analyzed on 517 patients treated by ch-EVAR from 2008 from 2014 by prearranged defined and documented protocols. RESULTS: A total of 119 patients in US centers and 398 in European centers …